Product Main Function
1. Measurement of AC/DC leakage current.
2. Range: 0mA~60.0A AC/DC
3. Resolution: 1mA AC/DC
4. Accuracy: ±2%rdg±5dgt
5. Data Storage: 99 groups
6. Line Voltage: below 600V
7. CT Size: 25mm x 30mm
The meter with the functions of peak hold, data hold and data storage, and equipped with interface, communication cable and monitoring software. It can real time monitoring and query history online via the computer, and display dynamically, has the maximum, the minimum and the average value indication, with the alarm value setting and the alarm indication function, has the historical data reading, saves, prints and other functions.
Function |
Measurement of AC/DC leakage current, current, Car DC dark current, leakage current, starting current. |
Power Supply |
Alkaline dry battery 6LR61,9V |
Test Mode |
Clamp CT, non-contact measurement |
Display Mode |
4 digital LCD display |
Meter Dimension |
175mm(L)×70mm(W)×38mm(H) |
LCD Dimension |
35mm×21.5mm; display area:32mm×15mm |
Sampling Rate |
2 times/second |
Frequency Response |
AC: 45Hz-400Hz |
Polarity Indication |
In DC current test auto identified and display“—” symbol |
CT Size |
25mm×30mm |
Conductor Position |
The tested conductor is in the center of the clamp |
Shift |
Automatically |
Line Voltage |
Do not exceedAC 600V |
Communication Interface |
With USB interface, storage data can be uploaded to computer, software monitoring |
Communication Parameter |
Baud rate:9600, data bit:8, stop bit:1, check bit: NONE |
Data Storage |
99 groups, flashes display "FULL" symbol indicate the storage full |
Data Hold |
Data hold function: "DH" symbol display |
Overflow Display |
Exceed measure range overflow function: "OL" symbol display |
Automatic Shutdown |
5 Minutes after power on will shutdown automatically without any operation |
Battery Voltage |
When battery voltage lower than 7.2V, the low battery voltage symbol will display,and remind to replace the battery |
MeterWeight |
240g |
Working Current |
<20mA |
Working Temperature |
-10°C-50°C, below 80%rh |
Limit Temperature Error |
|
Store Temperature |
-10°C-60°C,below 70%rh |
Insulating Strength |
AC 2KV/rms. (between iron core and shell) |
Suitable Safe Standard |
IEC1010-1,IEC1010-2-032,pollution:2,CAT III (600V) |
Accessories |
Meter: 1PCS; Communication cable: 1PCS; Software CD: 1PCS; Cloth bag: 1PCS |
Model | Description | Range | Resolution | Clamp size |
ETCR6000 | AC/DC Clamp Leakage Current Meter | AC/DC 0mA~60.0A | 1mA | Φ7mm |
ETCR6000B | AC/DC Clamp Leakage Current Meter | AC/DC 0mA~60.0A | 1mA | 16x18mm |
ETCR6100 | AC/DC Clamp Current Meter | AC/DC 0.0A~1000A | 0.1A | 30×35mm |
ETCR6200 | AC/DC Clamp Leakage Current Meter | AC/DC 0mA~60.0A | 1mA | 25×30mm |
ETCR6300 | AC Clamp Leakage Current Meter | AC 0.000mA~60.00A | 1uA | |
ETCR6300D | DC Clamp Leakage Current Meter | DC 0.0mA~6.0A | 0.1mA | |
ETCR6500 | AC Clamp Leakage Current Meter | AC 0.00mA~300.0A | 0.01mA | 35×40mm |
ETCR6600 | AC Clamp Leakage Current Meter | AC 0mA~600A | 1mA | |
ETCR6800 | AC Clamp Leakage Current Meter | AC 0.00mA~1200A | 0.01mA | Φ68mm |
ETCR6800D | AC/DC Clamp Current Meter |
AC 0.0A~1500A DC0.0A~2000A |
0.1A |
Package |
Outer Package |
Carton |
Inner Package |
Cloth bag | |
Accessory |
Meter | 1 PCS |
Monitoring Software (CD) | 1 COPY | |
Special Communication Cable | 1 PCS | |
Package box | 1 PCS | |
Manual/ Warranty Card/ Certificate | 1 SET |
The meter with the functions of peak hold, data hold and data storage, and equipped with interface, communication cable and monitoring software. It can real time monitoring and query history online via the computer, and display dynamically, has the maximum, the minimum and the average value indication, with the alarm value setting and the alarm indication function, has the historical data reading, saves, prints and other functions.
Function |
Measurement of AC/DC leakage current, current, Car DC dark current, leakage current, starting current. |
Power Supply |
Alkaline dry battery 6LR61,9V |
Test Mode |
Clamp CT, non-contact measurement |
Display Mode |
4 digital LCD display |
Meter Dimension |
175mm(L)×70mm(W)×38mm(H) |
LCD Dimension |
35mm×21.5mm; display area:32mm×15mm |
Sampling Rate |
2 times/second |
Frequency Response |
AC: 45Hz-400Hz |
Polarity Indication |
In DC current test auto identified and display“—” symbol |
CT Size |
25mm×30mm |
Conductor Position |
The tested conductor is in the center of the clamp |
Shift |
Automatically |
Line Voltage |
Do not exceedAC 600V |
Communication Interface |
With USB interface, storage data can be uploaded to computer, software monitoring |
Communication Parameter |
Baud rate:9600, data bit:8, stop bit:1, check bit: NONE |
Data Storage |
99 groups, flashes display "FULL" symbol indicate the storage full |
Data Hold |
Data hold function: "DH" symbol display |
Overflow Display |
Exceed measure range overflow function: "OL" symbol display |
Automatic Shutdown |
5 Minutes after power on will shutdown automatically without any operation |
Battery Voltage |
When battery voltage lower than 7.2V, the low battery voltage symbol will display,and remind to replace the battery |
MeterWeight |
240g |
Working Current |
<20mA |
Working Temperature |
-10°C-50°C, below 80%rh |
Limit Temperature Error |
|
Store Temperature |
-10°C-60°C,below 70%rh |
Insulating Strength |
AC 2KV/rms. (between iron core and shell) |
Suitable Safe Standard |
IEC1010-1,IEC1010-2-032,pollution:2,CAT III (600V) |
Accessories |
Meter: 1PCS; Communication cable: 1PCS; Software CD: 1PCS; Cloth bag: 1PCS |
Model | Description | Range | Resolution | Clamp size |
ETCR6000 | AC/DC Clamp Leakage Current Meter | AC/DC 0mA~60.0A | 1mA | Φ7mm |
ETCR6000B | AC/DC Clamp Leakage Current Meter | AC/DC 0mA~60.0A | 1mA | 16x18mm |
ETCR6100 | AC/DC Clamp Current Meter | AC/DC 0.0A~1000A | 0.1A | 30×35mm |
ETCR6200 | AC/DC Clamp Leakage Current Meter | AC/DC 0mA~60.0A | 1mA | 25×30mm |
ETCR6300 | AC Clamp Leakage Current Meter | AC 0.000mA~60.00A | 1uA | |
ETCR6300D | DC Clamp Leakage Current Meter | DC 0.0mA~6.0A | 0.1mA | |
ETCR6500 | AC Clamp Leakage Current Meter | AC 0.00mA~300.0A | 0.01mA | 35×40mm |
ETCR6600 | AC Clamp Leakage Current Meter | AC 0mA~600A | 1mA | |
ETCR6800 | AC Clamp Leakage Current Meter | AC 0.00mA~1200A | 0.01mA | Φ68mm |
ETCR6800D | AC/DC Clamp Current Meter |
AC 0.0A~1500A DC0.0A~2000A |
0.1A |
Package |
Outer Package |
Carton |
Inner Package |
Cloth bag | |
Accessory |
Meter | 1 PCS |
Monitoring Software (CD) | 1 COPY | |
Special Communication Cable | 1 PCS | |
Package box | 1 PCS | |
Manual/ Warranty Card/ Certificate | 1 SET |