Product Characteristics
1:Between metal components of equipotential connection resistance test,low value resistance test, DC resistance test, contact resistance test, riveting resistance test, wire length test, etc.
2:Range:0.0001Ω~30.00kΩ
3: Data Storage :400 groups
4:Alarm Fuction : Audible alarm
ETCR3700 Milliohm Meter adopt precise 4-wire method to measure, measurement more accurate. Micro ohmmeter function.Between metal components of equipotential connection resistance test, low value resistance test, DC resistance test, contact resistance test, riveting resistance test, wire length test, etc.Range:0.0001Ω~30.00kΩ。 Alarm function, clock function, storage function, data upload function, storage data can be uploaded to computer, save and print.
Function | Between metal components of equipotential connection resistance test, low value resistance test, DC resistance test, contact resistance test, riveting resistance test, wire length test, etc. | |||
Power Supply | DC 7.4V 2.6Ah, rechargeable lithium battery, full charge about 8.4V | |||
Test Current | ≥2A | |||
Detection Mode | Precision 4-wire method, two channel A/D simultaneous detection | |||
Range, Accuracy,Resolution | 0.0001Ω~0.3000Ω; ±1%rdg±10dgt; 0.0001Ω | |||
0.300Ω~3.000Ω; ±1%rdg±5dgt | ||||
3.000Ω~30.00Ω ; ±1%rdg±5dgt ; 0.01Ω | ||||
30.0Ω~300.0Ω; ±1%rdg±5dgt ; 0.1Ω | ||||
300Ω~3000Ω; ±1%rdg±5dgt ; 1Ω | ||||
30.00kΩ~30.00kΩ; ±1%rdg±5dgt ; 0.01kΩ | ||||
Wire length Test | L:≤999999m | |||
Standard wire length | Standard wire length setting range: 1m~30m | |||
Test Interface | C1 current positive, C2 current negative, P1 voltage positive, P2 voltage negative | |||
Measurement Time | 2second/times | |||
Data Storage | 400 groups (Power down or replace battery will not lose the data) | |||
Alarm Setting | Alarm critical value setting range; 1Ω~30Ω, 00Ω will not start the alarm function. Will not start the alarm function in start up every time | |||
Alarm Function | Measure value exceed alarm setting value, will "Toot-toot-toot" alarm indication | |||
Test instruction | The blue TESTING light flashes during the test | |||
Charge Indication | In charging, the charger indicator lamp light on red, full charge light on green | |||
Data Hold | The test result is kept to display automatically after each test | |||
Test Wire | 4PCS: red and black each for 2PCS, each wire length 5M | |||
Backlight Function | Yes, suitable for the dim place | |||
Display Mode | LCD: 128mm×75mm | |||
Host Size | 212mm×175mm×83mm | |||
Weight | 950g | |||
Line voltage | Live line measurement should be avoided | |||
Overflow Indication | Exceed measure range overflow function: “OL” symbol display | |||
Low Voltage Indication | When battery voltage is lower than 6.8V±0.1V, low battery voltage symbol will display and remind to replace battery. | |||
Working Temperature and Humidity | -10℃~40℃;below 80%rh | |||
Storage Temperature and Humidity | -10℃~60℃;below 70%rh | |||
Charging interface | Yes | |||
USB Interface | With USB interface, software monitoring, storage data can be uploaded to computer, save and print. | |||
Withstand Voltage | AC 3700V/rms | |||
Suitable Safety Standard | IEC61010-1,CAT Ⅲ 600V,Polluted Gradation | |||
JJG724-1991【Verification regulation of DC digital ohmmeter】 | ||||
JJG166-19939【Verification regulation of DC resistor】 | ||||
DL/T967-2005【Verification regulation of loop resistance tester and DC resistance rapid tester】 |
Model | Test Current | Range | Resolution | Remark |
ETCR3700 | ≥2A | 1mΩ~30.00KΩ | 0.1mΩ | Normal version |
ETCR3700C | ≥4A | 1mΩ~30.00KΩ | 0.1mΩ | Waterproof protection box enclosure |
Tester | 1PC |
USB data transmission cable | 1PCS |
Software CD | 1COPY |
Tester bag | 1PC |
Charger | 1PC |
Test Wires | 4pcs(2 red and 2 black) |
Manual、Warranty Card、Certificate | 1pcs |
ETCR3700 Milliohm Meter adopt precise 4-wire method to measure, measurement more accurate. Micro ohmmeter function.Between metal components of equipotential connection resistance test, low value resistance test, DC resistance test, contact resistance test, riveting resistance test, wire length test, etc.Range:0.0001Ω~30.00kΩ。 Alarm function, clock function, storage function, data upload function, storage data can be uploaded to computer, save and print.
Function | Between metal components of equipotential connection resistance test, low value resistance test, DC resistance test, contact resistance test, riveting resistance test, wire length test, etc. | |||
Power Supply | DC 7.4V 2.6Ah, rechargeable lithium battery, full charge about 8.4V | |||
Test Current | ≥2A | |||
Detection Mode | Precision 4-wire method, two channel A/D simultaneous detection | |||
Range, Accuracy,Resolution | 0.0001Ω~0.3000Ω; ±1%rdg±10dgt; 0.0001Ω | |||
0.300Ω~3.000Ω; ±1%rdg±5dgt | ||||
3.000Ω~30.00Ω ; ±1%rdg±5dgt ; 0.01Ω | ||||
30.0Ω~300.0Ω; ±1%rdg±5dgt ; 0.1Ω | ||||
300Ω~3000Ω; ±1%rdg±5dgt ; 1Ω | ||||
30.00kΩ~30.00kΩ; ±1%rdg±5dgt ; 0.01kΩ | ||||
Wire length Test | L:≤999999m | |||
Standard wire length | Standard wire length setting range: 1m~30m | |||
Test Interface | C1 current positive, C2 current negative, P1 voltage positive, P2 voltage negative | |||
Measurement Time | 2second/times | |||
Data Storage | 400 groups (Power down or replace battery will not lose the data) | |||
Alarm Setting | Alarm critical value setting range; 1Ω~30Ω, 00Ω will not start the alarm function. Will not start the alarm function in start up every time | |||
Alarm Function | Measure value exceed alarm setting value, will "Toot-toot-toot" alarm indication | |||
Test instruction | The blue TESTING light flashes during the test | |||
Charge Indication | In charging, the charger indicator lamp light on red, full charge light on green | |||
Data Hold | The test result is kept to display automatically after each test | |||
Test Wire | 4PCS: red and black each for 2PCS, each wire length 5M | |||
Backlight Function | Yes, suitable for the dim place | |||
Display Mode | LCD: 128mm×75mm | |||
Host Size | 212mm×175mm×83mm | |||
Weight | 950g | |||
Line voltage | Live line measurement should be avoided | |||
Overflow Indication | Exceed measure range overflow function: “OL” symbol display | |||
Low Voltage Indication | When battery voltage is lower than 6.8V±0.1V, low battery voltage symbol will display and remind to replace battery. | |||
Working Temperature and Humidity | -10℃~40℃;below 80%rh | |||
Storage Temperature and Humidity | -10℃~60℃;below 70%rh | |||
Charging interface | Yes | |||
USB Interface | With USB interface, software monitoring, storage data can be uploaded to computer, save and print. | |||
Withstand Voltage | AC 3700V/rms | |||
Suitable Safety Standard | IEC61010-1,CAT Ⅲ 600V,Polluted Gradation | |||
JJG724-1991【Verification regulation of DC digital ohmmeter】 | ||||
JJG166-19939【Verification regulation of DC resistor】 | ||||
DL/T967-2005【Verification regulation of loop resistance tester and DC resistance rapid tester】 |
Model | Test Current | Range | Resolution | Remark |
ETCR3700 | ≥2A | 1mΩ~30.00KΩ | 0.1mΩ | Normal version |
ETCR3700C | ≥4A | 1mΩ~30.00KΩ | 0.1mΩ | Waterproof protection box enclosure |
Tester | 1PC |
USB data transmission cable | 1PCS |
Software CD | 1COPY |
Tester bag | 1PC |
Charger | 1PC |
Test Wires | 4pcs(2 red and 2 black) |
Manual、Warranty Card、Certificate | 1pcs |