Product Main Function
1. AC current test,range:0.0mA~300A
2. AC voltage test,range:0V~700V
3. Phase between voltage and current,range:0.0°~360°
4. Make-break resistance value,range:0.00kΩ~20.0kΩ
5. Maximum current of up and down stroke of pumping unit, stroke ratio, up and down stroke time, stroke times per minute.
6. Line Voltage:below 600V
7. CT Size:35mm x 40mm
ETCR4800 Pumping Unit Multimeter, is an instrument specially designed for oilfield field measurement,Simultaneously measurement AC current(range:0.0mA~300A)、voltage(range:0V~700V)、frequency(range:10Hz~70Hz)、phase between voltage and current(range:0.0°~360.0°)、make-break resistance value(range:0.00kΩ~20.0kΩ)、maximum current of up and down stroke of pumping unit, stroke ratio, up and down stroke time, stroke times per minute. LCD display 240dots×160dots,All measured data are displayed on the screen, so that the working condition of the pumping unit can be easily judged.
ETCR4800 Pumping Unit Multimeter is equipped with a rechargeable Ni-MH battery, a charger and a charging interface, which is convenient for long-term online use.The meter can store 1000 groups of data . USB interface with data upload function , storage data can be uploaded to the computer,save and print.
Power Supply | DC7.2V 1.2V AAX6PCS NI-MH battery 1200mAH |
CT Size | 35mm x 40mm |
LCD Size | 240dotsX160dots(with back light) |
Rang | Voltage :AC 0V~700V |
Current:AC 0.0mA~300A | |
Phse:0°~360° | |
Resistance:0.00Kohm~20.0Kohm | |
Frequency:10.0Hz~70.0Hz | |
Resolution | Voltage:AC 1V |
Current:AC 0.1mA | |
Phase :1° | |
Resistance :10ohm | |
Frequency:0.1Hz | |
Accuracy | Voltage :±(1.5%rdg+3dgt) |
Current:±(1.5%rdg+3dgt) | |
Phase:±3° | |
Resolution:±(2.0%rdg+3dgt) | |
Frequency:±(2.0%rdg+3dgt) | |
Measure Amplitude Of The Phase Frequency | Voltage:30V~700V |
Current:30mA~300A | |
Data storage | 1000 groups |
Communication Interface | USB interface,storage data can be uploaded to computer |
Auto Shut Down | 15 minutes after boot up, the meter shuts down automatically without any operation |
Working Current | Meter power consumption of open backlight: 50mA |
Meter power consumption of close backlight: 30mA | |
Working Temperature | -20℃~40℃; below 80%Rh |
Storage temperature | -10℃~60℃;below 70%Rh |
Well Number Quantity | 100 number |
Well No. Setting | 15-bit code, The well number can be edited by the instrument or the upper computer software |
Clock Function | Yes |
Password Setting | Yes, 6 digital password |
Cable Length | Test wire length 1.5m |
Current lamp wire length | 2m |
Detection Rate | About 2second/times |
Input Impedance | Test voltage input impedance: 1MΩ |
Voltage Detection | The meter displays the battery voltage in real time. When the battery voltage is lower than 6.5v, low battery voltage symbol will display, please charge in time |
Resistant to pressure | Ac voltage of sine wave to withstand 1000v/50hz between instrument line and housing for 1 minute |
Insulation | ≥100mω between instrument line and sheath housing |
Structure | Double insulation, with insulated anti-vibration sheath |
Suitable for safety regulations | IEC61010-1 CAT Ⅲ 600V,IEC61010-031,IEC61326,Pollution degree 2 |
Weight | 1000g |
Dimension | 196mm×92mm×54mm |
Package | Outer Package | Carton |
Inner Package | Cloth bag | |
Accessory | Host | 1 PCS |
Current Clamp | 1PCS | |
Test wire | 4 PCS | |
Power adapter | 1 PCS | |
Communication line | 1PCS | |
Software CD | 1 COPY | |
Aluminium Case | 1 PCS | |
Manual | 1 PCS | |
Certification | 1 PCS | |
Warranty Card | 1 PCS |
ETCR4800 Pumping Unit Multimeter, is an instrument specially designed for oilfield field measurement,Simultaneously measurement AC current(range:0.0mA~300A)、voltage(range:0V~700V)、frequency(range:10Hz~70Hz)、phase between voltage and current(range:0.0°~360.0°)、make-break resistance value(range:0.00kΩ~20.0kΩ)、maximum current of up and down stroke of pumping unit, stroke ratio, up and down stroke time, stroke times per minute. LCD display 240dots×160dots,All measured data are displayed on the screen, so that the working condition of the pumping unit can be easily judged.
ETCR4800 Pumping Unit Multimeter is equipped with a rechargeable Ni-MH battery, a charger and a charging interface, which is convenient for long-term online use.The meter can store 1000 groups of data . USB interface with data upload function , storage data can be uploaded to the computer,save and print.
Power Supply | DC7.2V 1.2V AAX6PCS NI-MH battery 1200mAH |
CT Size | 35mm x 40mm |
LCD Size | 240dotsX160dots(with back light) |
Rang | Voltage :AC 0V~700V |
Current:AC 0.0mA~300A | |
Phse:0°~360° | |
Resistance:0.00Kohm~20.0Kohm | |
Frequency:10.0Hz~70.0Hz | |
Resolution | Voltage:AC 1V |
Current:AC 0.1mA | |
Phase :1° | |
Resistance :10ohm | |
Frequency:0.1Hz | |
Accuracy | Voltage :±(1.5%rdg+3dgt) |
Current:±(1.5%rdg+3dgt) | |
Phase:±3° | |
Resolution:±(2.0%rdg+3dgt) | |
Frequency:±(2.0%rdg+3dgt) | |
Measure Amplitude Of The Phase Frequency | Voltage:30V~700V |
Current:30mA~300A | |
Data storage | 1000 groups |
Communication Interface | USB interface,storage data can be uploaded to computer |
Auto Shut Down | 15 minutes after boot up, the meter shuts down automatically without any operation |
Working Current | Meter power consumption of open backlight: 50mA |
Meter power consumption of close backlight: 30mA | |
Working Temperature | -20℃~40℃; below 80%Rh |
Storage temperature | -10℃~60℃;below 70%Rh |
Well Number Quantity | 100 number |
Well No. Setting | 15-bit code, The well number can be edited by the instrument or the upper computer software |
Clock Function | Yes |
Password Setting | Yes, 6 digital password |
Cable Length | Test wire length 1.5m |
Current lamp wire length | 2m |
Detection Rate | About 2second/times |
Input Impedance | Test voltage input impedance: 1MΩ |
Voltage Detection | The meter displays the battery voltage in real time. When the battery voltage is lower than 6.5v, low battery voltage symbol will display, please charge in time |
Resistant to pressure | Ac voltage of sine wave to withstand 1000v/50hz between instrument line and housing for 1 minute |
Insulation | ≥100mω between instrument line and sheath housing |
Structure | Double insulation, with insulated anti-vibration sheath |
Suitable for safety regulations | IEC61010-1 CAT Ⅲ 600V,IEC61010-031,IEC61326,Pollution degree 2 |
Weight | 1000g |
Dimension | 196mm×92mm×54mm |
Package | Outer Package | Carton |
Inner Package | Cloth bag | |
Accessory | Host | 1 PCS |
Current Clamp | 1PCS | |
Test wire | 4 PCS | |
Power adapter | 1 PCS | |
Communication line | 1PCS | |
Software CD | 1 COPY | |
Aluminium Case | 1 PCS | |
Manual | 1 PCS | |
Certification | 1 PCS | |
Warranty Card | 1 PCS |