Product Main Function
Measurement of DC voltage, AC voltage, AC current true RMS, resistance, capacitance, frequency, on-off test, temperature, diode forward voltage drop and others parameters.
CT Size:Ф27mm
DC Voltage:0mV~600V
AC Voltage:0V-600V
AC Curent:0A-600A
Resistance:0Ω~40MΩ
Capacitance:0nF~10mF
Frequency:0Hz~40MHz
ETCR6420 Clamp Multimeter is a portable type clamp digital multimeter, which can measure DC voltage, AC voltage, current true RMS value, resistance, frequency, on-off test, temperature, forward voltage drop of the diode and other parameters. The capacitance measurement range is up to 10mF and the measurement speed of large capacitance is fast. The instrument with a small structure, easy to operate and portable. It is an ideal instrument for electrical measurement, which provides a safe, accurate and convenient new electric power meter for electric inspectors, and is an essential tool for electrical safety inspection.
1. Clamp
2. Trigger
3. SEL function selection key(Press this key continuously to loop through all functions of gear.)
4. Display LCD
5. “COM” commond input terminal(input grouding)
6. DH reading hold key: press this key can lock present reading value, and display “DH”symbol in the same time, press this key again to cancel the hold function, and the “DH” symbol disappear. Long Press “DH” 2 seconds to open or close the backlight.
7. Rotary switch
8. RANGE manual range key: When need to fixed one of measurement range, can use the manual range function.
9. “V/W” Common input positive terminal
10. RAN key: Press this key to cycle from small to large to select all measurement ranges of each function.
11. ProbeX2PCS
12. temperature transducerX1PCS
Basic function |
|
DC Voltage |
400m/4/40/400/600V ±(0.5%+5) |
AC Voltage |
4/40/400/600V ±(1.2%+5) |
AC Current |
4A/40A/400A/600A ±(2%+10) |
Resistance |
100/4k/40k/400k/4M/40MΩ ±(1%+5) |
10n/100n/1u/10u/100uF/1000uF/10mF ±(3%+5) |
|
Frequency |
10/100/1k/10k/100k/1M/10m/40MHz ±(0.5%+3) |
Temperature |
-50°C~1000°C ±(1%+4) |
Special function |
|
Auto Range |
√ |
ManualRange |
√ |
AC ConversionType |
true RMS |
InputProtection |
√ |
Auto Shutdown |
about 10 minutes, can be setand cancel auto shutdown function |
Diode Test |
Can measure the LED work voltage below 3V |
Duty Ratio Measurement |
√ |
NCV(Live line)Measurement |
√ |
Short Circuit Buzzer |
√ |
LowVoltageIndicator |
√ |
Input Impedance |
About10MΩ |
Data Hold |
√ |
Blue Backlight |
√ |
CT Size |
Ф27mm |
General features |
|
Power Supply |
AAA1.5VX2 |
Weight |
230g(with battery) |
Meter Dimension |
213X80X35mm |
Accessories |
Meter:1pcs;Pen probe:1set;Temperature sensor:1pcs;Tester Bag:1pcs |
Model |
CT |
DC Voltage |
AC Voltage |
DC Current |
AC Current |
Resistance |
ETCR6420 |
Ф27mm |
0mV-600V |
0V-600V |
/ |
0A-600A |
0Ω-40MΩ |
ETCR6450 |
Ф52mm |
0mV-1000V |
0mV-700V |
0A-1000A |
0A-1000A |
0Ω-40MΩ |
ETCR6470 |
Ф55mm |
0V - 2000V |
0V - 2000V |
/ |
0A-2000A |
0Ω-20MΩ |
Package |
Outer Package |
Carton |
Inner Package |
Cloth bag |
|
Accessory |
Meter |
1 PCS |
Pen probe |
1 PCS |
|
Temperature sensor |
1 PCS |
|
Manual |
1 PCS |
|
Certification |
1 PCS |
|
Warranty Card |
1 PCS |
ETCR6420 Clamp Multimeter is a portable type clamp digital multimeter, which can measure DC voltage, AC voltage, current true RMS value, resistance, frequency, on-off test, temperature, forward voltage drop of the diode and other parameters. The capacitance measurement range is up to 10mF and the measurement speed of large capacitance is fast. The instrument with a small structure, easy to operate and portable. It is an ideal instrument for electrical measurement, which provides a safe, accurate and convenient new electric power meter for electric inspectors, and is an essential tool for electrical safety inspection.
1. Clamp
2. Trigger
3. SEL function selection key(Press this key continuously to loop through all functions of gear.)
4. Display LCD
5. “COM” commond input terminal(input grouding)
6. DH reading hold key: press this key can lock present reading value, and display “DH”symbol in the same time, press this key again to cancel the hold function, and the “DH” symbol disappear. Long Press “DH” 2 seconds to open or close the backlight.
7. Rotary switch
8. RANGE manual range key: When need to fixed one of measurement range, can use the manual range function.
9. “V/W” Common input positive terminal
10. RAN key: Press this key to cycle from small to large to select all measurement ranges of each function.
11. ProbeX2PCS
12. temperature transducerX1PCS
Basic function |
|
DC Voltage |
400m/4/40/400/600V ±(0.5%+5) |
AC Voltage |
4/40/400/600V ±(1.2%+5) |
AC Current |
4A/40A/400A/600A ±(2%+10) |
Resistance |
100/4k/40k/400k/4M/40MΩ ±(1%+5) |
10n/100n/1u/10u/100uF/1000uF/10mF ±(3%+5) |
|
Frequency |
10/100/1k/10k/100k/1M/10m/40MHz ±(0.5%+3) |
Temperature |
-50°C~1000°C ±(1%+4) |
Special function |
|
Auto Range |
√ |
ManualRange |
√ |
AC ConversionType |
true RMS |
InputProtection |
√ |
Auto Shutdown |
about 10 minutes, can be setand cancel auto shutdown function |
Diode Test |
Can measure the LED work voltage below 3V |
Duty Ratio Measurement |
√ |
NCV(Live line)Measurement |
√ |
Short Circuit Buzzer |
√ |
LowVoltageIndicator |
√ |
Input Impedance |
About10MΩ |
Data Hold |
√ |
Blue Backlight |
√ |
CT Size |
Ф27mm |
General features |
|
Power Supply |
AAA1.5VX2 |
Weight |
230g(with battery) |
Meter Dimension |
213X80X35mm |
Accessories |
Meter:1pcs;Pen probe:1set;Temperature sensor:1pcs;Tester Bag:1pcs |
Model |
CT |
DC Voltage |
AC Voltage |
DC Current |
AC Current |
Resistance |
ETCR6420 |
Ф27mm |
0mV-600V |
0V-600V |
/ |
0A-600A |
0Ω-40MΩ |
ETCR6450 |
Ф52mm |
0mV-1000V |
0mV-700V |
0A-1000A |
0A-1000A |
0Ω-40MΩ |
ETCR6470 |
Ф55mm |
0V - 2000V |
0V - 2000V |
/ |
0A-2000A |
0Ω-20MΩ |
Package |
Outer Package |
Carton |
Inner Package |
Cloth bag |
|
Accessory |
Meter |
1 PCS |
Pen probe |
1 PCS |
|
Temperature sensor |
1 PCS |
|
Manual |
1 PCS |
|
Certification |
1 PCS |
|
Warranty Card |
1 PCS |