ETCR3200 Double Clamp Multi-function Grounding Resistance Tester+etcr

ETCR3200 Double Clamp Multi-function Grounding Resistance Tester

Product Characteristics

1:2/3/4-wire method measure earth resistance,Range:0.00Ω~30.00kΩ

 2:Selection method meausre earth resistance, Range: 0.00Ω~3000Ω

 3:Doule clamp method measure earth resistance,Range: 0.01~100Ω

4:Soil resistivity measurement, Range:0.00Ωm~9000kΩm

5:Earth voltage measurement,Range:AC 0~600V

6:AC current measurement, Range: 0.01mA~600A

7:Data storage: 2000 sets

8:Alarm function: audible and visual alarm

9:CT size: Φ68mm

ETCR3200 Double Clamp Earth Resistance Tester, through a variety of methods measuring earth resistance (range: 0.01Ω ~ 30.00 kΩ), soil resistivity (range: 0.01Ωm ~ 9000kΩm), earth voltage (range: 0.1 V ~ 100.0 V), grounding lead leakage current, AC current (range: 0.01mA ~ 600A); The tester adopts the precision 4-wire method, 3-wire method, simple 2-wire method, selection method and double-clamp method to measure grounding resistance. Large caliber current clamp design, can measure the grounding system which using large grounding down lead.It can flexibly and accurately measure arbitrary grounding resistance values of single point and mesh grounding and other complex grounding conditions. When measuring parallel grounding, it is unnecessary to disconnect any parallel grounding electrode to maximize the convenience of measurement. Import FFT (fast Fourier transform) technology, AFC (automatic frequency control) technology, ensure the measurement of  high precision, high stability and reliability.

ETCR3200 Double Clamp Multi-function Grounding Resistance Tester is composed of host machine, current clamp, monitoring software, test wires, auxiliary ground rod and communication cable. Host machine with large LCD display, white backlight, bar chart indication, clear at a glance. It can store 2000 sets of data at the same time, through the monitoring software to relize historical access and online real-time monitoring functions, dynamic display, alarm indication and auto shut down, with historical data reading, accessing, saving, reporting, printing and other functions.

ETCR3200 Double Clamp Multi-function Grounding Resistance Tester



 
 Power Supply  DC 9V Alkaline dry cell LR14 1.5V*6PCS, continues standby 300 hours
 LCD Size  124mm x 67mm(with backlight)
 Range  Selection measurement method :0.01Ω - 3000Ω
 Double clamp measurement method :0.01Ω - 100Ω
 2/3/4 pole measurement method :0.01Ω - 30.00kΩ
 Soil Resistivity :0.01Ωm - 9000KΩ
 DC Resistance:0.01Ω - 30.00kΩ
 Earth Voltage:0.1V -100.0V
 AC Current:0.01mA -600A
 Resolution  Resistance:0.01Ω
 Soil Resistivity :0.01Ωm
 Current:0.01mA
 Voltage:0.1V
 Max Accuracy  ±2%rdg±3dgt
 Data Storage  2000 groups
 Data Upload  RS232 interface, storage data can be uploaded to computer, saved or printed.
 Automatic Shut Down  Automatically shut down after 15 minutes start up
 Power Consumption  Turn on the backlight: 45mA Max
 Turn off the backlight : 25mA Max
 Measurement: 100mA Max(Backlight shut off)
 Working Temperature & Humidity  -10℃-40℃, below 80%rh
 Storage temperature & humidity  -20℃-60℃, below 70%rh
 Clamp Caliber  Φ68mm
 Measuring Method  2/3/4 pole measurement method: Change-pole method, measurement current 20mA Max
 Selection measurement method: Change-pole method, measurement current 20mA Max
 Double clamp measurement method: Non-connect mutual inductance method, measurement current 1mA Max
 Soil Resistivity: 4-pole measurement (Wenner method)
 AC current: Mutual inductance method(clamp)
 Earth Voltage: Average rectification(between P(S)-ES)
 Test Frequency  128Hz/111Hz/105Hz/94Hz(AFC)
Data Model  Average value,maximum,minimum value
 line resistance check  Automatic calibration
 Measuring Rate  AC current: about 0.5 times/second
 Earth Voltage: about 0.5 times/second
 Earth resistance,soil resistivity: about 5 seconds/time
 Measuring Times  Over 5000 times (Short-circuit test, interval time should be at least 30seconds)
 Short-circuit Test Current  AC 20mA max
 Open-circuit Test Voltage  AC 40V max
 Test Voltage Wave  Sine wave
 Electrode Distance Range 1m-100m
 Line Voltage  Measurement below AC 600V
 Data Hold  Data hold function: “HOLD” symbol display
 Data Access  Data read function: “READ” symbol display
 Overflow Display  Exceed measuring range overflow function: “OL” symbol display
 Auxiliary Grounding Test  With auxiliary grounding resistance test function, 0.00KΩ-30kΩ(100R+rC<50kΩ, 100R+rP<50kΩ)
 Interference Test  Automatic identification of interference signals, “NOISE” symbol indication when the interference voltage is higher than 5V
 Alarm Function  Measuring value exceeds alarm setting value, will "Toot-toot-toot" alarm hint
 Battery Voltage  While battery voltage decreases to around 7.5V, will display battery voltage low symbol“     ”, and reminding to replace the battery
 Overload Protection  Measure earth resistance: between each interfaces of E-P、E-E- C,AC 280V/3 seconds
 Insulation Resistance  Over 20MΩ(between circuit and outside shell is 500V)
 Withstand Voltage  AC 3700V/rms. (Between circuit and outside shell)
 Electromagnetic Features  IEC61010- 4-3,Wireless frequency electromagnetic field ≤1 V/m
 Protection Type   IEC61010-1(CAT Ⅲ 300V、CAT IV 150V、Pollution 2);
 IEC61010-031;
 IEC61557-1(Earth resistance);
 IEC61557-5(Soil resistivity);
 JJG 366-2004(Grounding resistance meter)
 Weight 1653g
 Meter Dimension  215mm(L)×190mm(W)×95mm(H)

Model

Earth Resistance 

(Ω)


Selection Method 

Measure Resistance


(Ω)

Double Clamp 

Method Measure 

Resistance

(Ω)

Soil Resistivity

(Ωm)

Earth Voltage

(V)

AC Current

(A)

Data Storage

(group)

Remark
ETCR3000 0.01~2000 None None None 0~600 None 400 Normal type
ETCR3000C 0.01~2000 None None None 0~600 None 400 Waterproof protective shell
ETCR3000B 0.01~30000 None None 0.00~9000k 0~600 None 300 Normal type
ETCR3100C 0.01~30000 None None 0.00~9000k 0~600 None 300 Waterproof protective shell
ETCR3200 0.01~30000 0.01~3000 0.01~100 0.00~9000k 0.0~100.0 0.00mA~600A 2000 Normal type
ETCR3200C 0.01~30000 0.01~3000 0.01~100 0.00~9000k 0.0~100.0 0.00mA~600A 2000 Waterproof protective shell

  Package  Outer package  Carton
 Inner package  Aluminum case
 Accessory  Meter 1 PCS
 Current clamp   2 PCS
 Aluminum case 1 PCS
 Auxiliary grounding rod(10x150mm) 4 PCS
 Test cable yellow 10 meters 1 PCS
 Test cable green 10 meters 1 PCS
 Test cable red 20 meters 1 PCS
 Test cable black 20 meters 1 PCS
 Test cable black1.6 meters 1 PCS
 Test cable red 1.6 meters 1 PCS
 RS232 communication cable 1 PCS
 CD 1 PCS
 Manual 1 PCS
 Certificate 1 PCS
 Warranty Card 1 PCS