ETCR6100 AC/DC Clamp Current Meter-ETCR

ETCR6100 AC/DC Clamp Current Meter

Product Main Function

1. Measurement of AC/DC current, Range: 0.0A~1000A

2. Data Storage: 99 groups

3. Peak Hold

4. Line Voltage: below 600V

5. CT Size: 30mm x 35mm


ETCR6100 AC/DC Clamp Current Meter suitable for measuring AC, DC leakage current below 600V, range: AC/DC 0.0A~1000A, CT size: 30mmx35mm, especially suitable for places with dense flat cable (power metering system, high-speed rail system, automobile circuit maintenance, etc.). Non-contact current measurement, safe and simple operation.The instrument is small size, high accuracy, performance stable and function perfect, which is one of the necessary tools for electrician safety inspection and maintenance.

The instrument with data hold, data storage and other functions, can store 99 groups of data, the instrument connect computer by interface, stotage data can be uploaded to the computer, easy to read, analysis, save, print and so on.


Model

 ETCR6100

CT Size

 30mm×35mm

Range

 DC/AC 0.0A~1000A

Accuracy

 ±2%rdg±3dgt

Resolution

 0.1A

Meter Size

 175mm×70mm×38mm

Meter Weight

 200g

Working Current

10mA

Function

Measurement of DC current, AC current, peak hold, on-line monitoring

Power Supply

 6LR61 9V

Test Mode

 Clamp CT, Non-contact measurement

Display Mode

 4digits LCD display

LCD Dimension

 35mm×21.5mm;display area:32mm×15mm

Sampling Rate

 About 2 times/s

Frequency

 AC 45Hz ~ 400Hz

Polar Indication

 Automatic identification for DC current detecting, display "-" symbol

Wire Position

 The tested wire should be in the center of the clamp jaw, clamp with off-center position will increase the error for max 1.5%rdg

Shift

 Automatically

Line Voltage

 Line measurement below DC 600V

Software

 Yes, the storage data of the meter can upload to computer by software

Data Storage 

 99 groups, flashing display FULL symbol indicate storage is full

Peak Hold

 Peak value capture and hold function, during the testing, long press the HOLD key to display the peak value.

Data Hold

 Data hold function: DH symbol display

Overflow display

 Exceed measure range overflow function: OL symbol display

Auto Shut Down

 5 Minutes after power on, the meter shuts down automatically without any operation to reduce battery consumption

Battery Voltage

 While battery voltage decreases to around 7.2V, will display low battery voltage symbol“    ”, and remind to replace the battery

Working Temperature

 -10℃ ~ 50℃,below 80%rh

Limit Temperature Error

 -10℃~0℃ and 40℃~50℃, the maximum increase in error is 2%rdg

Storage Temperature

 -10℃ ~60℃,below 70%rh

Insulating Strength

 AC2KV/rms (between the core and outside shell)

Suitable Safety Standard

IEC1010-1、IEC1010-2-032、pollution, etc 2、CAT Ⅲ(600V)



Model Description Range Resolution Clamp size
ETCR6000 AC/DC Clamp Leakage Current Meter AC/DC  0mA~60.0A 1mA Φ7mm
ETCR6000B AC/DC Clamp Leakage Current Meter AC/DC  0mA~60.0A 1mA 16x18mm
ETCR6100 AC/DC Clamp  Current Meter AC/DC  0.0A~1000A 0.1A 30×35mm
ETCR6200 AC/DC Clamp Leakage Current Meter AC/DC  0mA~60.0A 1mA 25×30mm
ETCR6300 AC Clamp Leakage Current Meter AC  0.000mA~60.00A 1uA
ETCR6300D DC Clamp Leakage Current Meter DC  0.0mA~6.0A 0.1mA
ETCR6500 AC Clamp Leakage Current Meter AC  0.00mA~300.0A 0.01mA 35×40mm
ETCR6600 AC Clamp Leakage Current Meter AC  0mA~600A 1mA
ETCR6800 AC Clamp Leakage Current Meter AC  0.00mA~1200A 0.01mA Φ68mm
ETCR6800D AC/DC Clamp Current Meter

AC  0.0A~1500A

DC 0.0A~2000A

0.1A

 Package  Outer Package  Carton
 Inner Package  Cloth bag
 Accessory  Meter  1 PCS
 Communication Cable  1 PCS
 Software CD  1 COPY
 Cloth bag  1 PCS
 Manual  1 PCS
 Certificate  1 PCS
 Warranty Card  1 PCS

ETCR6100 Catalog