Product Main Function
1. Measurement of DC current , leakage current, Range:AC 0.0mA~6.0A
2. Data Storage: 99 groups
3. Peak Hold
4. Line Voltage: below 600V
5. CT Size: 25mm x 30mm
ETCR6300D DC Leakage Current Clamp Meter suitable for measuring DC current and leakage current below 600V, range: 0.0mA~6.0A, CT size: 25mm x 30mm, the iron core adopts magnetic shielding technology, almost unaffected by the external magnetic field, strong anti-interference ability. Especially suitable for high accuracy small current measurement, adopt non-contact current measurement, safe and simple operation.The instrument is small size, high accuracy, performance stable and function perfect, which is one of the necessary tools for electrician safety inspection and maintenance..
The instrument with data hold, data storage and other functions, can store 99 groups of data, the instrument connect computer by interface, stotage data can be uploaded to the computer, easy to read, analysis, save, print and so on.
Function |
Measurement of DC leakage current, DC current and automobile leakage maintenance. |
Power Supply |
6LR61 9V |
Test Mode |
Clamp CT, magnetically modulating |
CT Size |
25mmx30mm |
Range |
0.0mA~6.00A DC |
Accuracy (23℃±3℃, below 70%RH) |
Range:0.0mA~300.0mA;Resolution:0.1mA;Accuracy:±2%rdg±5dgt |
Range:0.30A~6.00A;Resolution:0.01A;Accuracy:±2%rdg±5dgt |
|
Shielding |
Double layer shielding, strong anti-interference ability |
Display Mode |
4digits LCD display |
Meter Dimension |
175mm(L)×70mm(W)×38mm(H) |
LCD Dimension |
35mm×21.5mm;display area:32mm×15mm |
Sampling Rate |
about 2 times/s |
Range Shift |
0.0mA - 6.00A AC automatically shift |
Zero Clearing Function |
Yes, before testing, press ZERO key to zero clearing |
Polar Indication |
Automatic identification, display "-" symbol |
Wire Position |
The tested wire in the center of the clamp jaw |
Line Voltage |
Line measurement below DC 600V |
USB Interface |
With USB interface, storage data can be uploaded to computer, software monitoring |
Data Storage |
99units, display FULL symbol indicate storage full |
Peak Hold |
Peak capture and hold function, long press HOLD key and not release can display peak value in measurement. |
Data Hold |
Data hold function:DH symbol display |
Overflow display |
Exceed measure range overflow function:OL symbol display |
Auto Shut Down |
5 Minutes after power on, the meter shuts down automatically without any operation to reduce battery consumption |
Battery Voltage |
While battery voltage decreases to around 7.2V, will display low battery voltage symbol“ ”, and remind to replace the battery |
Meter Weight |
210g |
Working Current |
20mA |
Working Temperature |
-10℃ ~50℃,below 80%rh |
Limit Temperature Error |
-10℃~0℃ and 40℃~50℃, the maximum increase in error is 2%rdg |
Storage Temperature |
-10℃ ~60℃,below 80%rh |
Insulating Strength |
AC3700V/rms (between the core and outside shell) |
Suitable Safety Standard |
IEC1010-1、IEC1010-2-032、pollution, etc 2、CATⅢ(600V) |
Model | Description | Range | Resolution | Clamp size |
ETCR6000 | AC/DC Clamp Leakage Current Meter | AC/DC 0mA~60.0A | 1mA | Φ7mm |
ETCR6000B | AC/DC Clamp Leakage Current Meter | AC/DC 0mA~60.0A | 1mA | 16x18mm |
ETCR6100 | AC/DC Clamp Current Meter | AC/DC 0.0A~1000A | 0.1A | 30×35mm |
ETCR6200 | AC/DC Clamp Leakage Current Meter | AC/DC 0mA~60.0A | 1mA | 25×30mm |
ETCR6300 | AC Clamp Leakage Current Meter | AC 0.000mA~60.00A | 1uA | |
ETCR6300D | DC Clamp Leakage Current Meter | DC 0.0mA~6.0A | 0.1mA | |
ETCR6500 | AC Clamp Leakage Current Meter | AC 0.00mA~300.0A | 0.01mA | 35×40mm |
ETCR6600 | AC Clamp Leakage Current Meter | AC 0mA~600A | 1mA | |
ETCR6800 | AC Clamp Leakage Current Meter | AC 0.00mA~1200A | 0.01mA | Φ68mm |
ETCR6800D | AC/DC Clamp Current Meter |
AC 0.0A~1500A DC 0.0A~2000A |
0.1A |
Package | Outer Package | Carton |
Inner Package | Cloth bag | |
Accessory | Meter | 1 PCS |
Communication Cable | 1 PCS | |
CD | 1 COPY | |
Cloth bag | 1 PCS | |
Manual | 1 PCS | |
Certificate | 1 PCS | |
Warranty Card | 1 PCS |
ETCR6300D DC Leakage Current Clamp Meter suitable for measuring DC current and leakage current below 600V, range: 0.0mA~6.0A, CT size: 25mm x 30mm, the iron core adopts magnetic shielding technology, almost unaffected by the external magnetic field, strong anti-interference ability. Especially suitable for high accuracy small current measurement, adopt non-contact current measurement, safe and simple operation.The instrument is small size, high accuracy, performance stable and function perfect, which is one of the necessary tools for electrician safety inspection and maintenance..
The instrument with data hold, data storage and other functions, can store 99 groups of data, the instrument connect computer by interface, stotage data can be uploaded to the computer, easy to read, analysis, save, print and so on.
Function |
Measurement of DC leakage current, DC current and automobile leakage maintenance. |
Power Supply |
6LR61 9V |
Test Mode |
Clamp CT, magnetically modulating |
CT Size |
25mmx30mm |
Range |
0.0mA~6.00A DC |
Accuracy (23℃±3℃, below 70%RH) |
Range:0.0mA~300.0mA;Resolution:0.1mA;Accuracy:±2%rdg±5dgt |
Range:0.30A~6.00A;Resolution:0.01A;Accuracy:±2%rdg±5dgt |
|
Shielding |
Double layer shielding, strong anti-interference ability |
Display Mode |
4digits LCD display |
Meter Dimension |
175mm(L)×70mm(W)×38mm(H) |
LCD Dimension |
35mm×21.5mm;display area:32mm×15mm |
Sampling Rate |
about 2 times/s |
Range Shift |
0.0mA - 6.00A AC automatically shift |
Zero Clearing Function |
Yes, before testing, press ZERO key to zero clearing |
Polar Indication |
Automatic identification, display "-" symbol |
Wire Position |
The tested wire in the center of the clamp jaw |
Line Voltage |
Line measurement below DC 600V |
USB Interface |
With USB interface, storage data can be uploaded to computer, software monitoring |
Data Storage |
99units, display FULL symbol indicate storage full |
Peak Hold |
Peak capture and hold function, long press HOLD key and not release can display peak value in measurement. |
Data Hold |
Data hold function:DH symbol display |
Overflow display |
Exceed measure range overflow function:OL symbol display |
Auto Shut Down |
5 Minutes after power on, the meter shuts down automatically without any operation to reduce battery consumption |
Battery Voltage |
While battery voltage decreases to around 7.2V, will display low battery voltage symbol“ ”, and remind to replace the battery |
Meter Weight |
210g |
Working Current |
20mA |
Working Temperature |
-10℃ ~50℃,below 80%rh |
Limit Temperature Error |
-10℃~0℃ and 40℃~50℃, the maximum increase in error is 2%rdg |
Storage Temperature |
-10℃ ~60℃,below 80%rh |
Insulating Strength |
AC3700V/rms (between the core and outside shell) |
Suitable Safety Standard |
IEC1010-1、IEC1010-2-032、pollution, etc 2、CATⅢ(600V) |
Model | Description | Range | Resolution | Clamp size |
ETCR6000 | AC/DC Clamp Leakage Current Meter | AC/DC 0mA~60.0A | 1mA | Φ7mm |
ETCR6000B | AC/DC Clamp Leakage Current Meter | AC/DC 0mA~60.0A | 1mA | 16x18mm |
ETCR6100 | AC/DC Clamp Current Meter | AC/DC 0.0A~1000A | 0.1A | 30×35mm |
ETCR6200 | AC/DC Clamp Leakage Current Meter | AC/DC 0mA~60.0A | 1mA | 25×30mm |
ETCR6300 | AC Clamp Leakage Current Meter | AC 0.000mA~60.00A | 1uA | |
ETCR6300D | DC Clamp Leakage Current Meter | DC 0.0mA~6.0A | 0.1mA | |
ETCR6500 | AC Clamp Leakage Current Meter | AC 0.00mA~300.0A | 0.01mA | 35×40mm |
ETCR6600 | AC Clamp Leakage Current Meter | AC 0mA~600A | 1mA | |
ETCR6800 | AC Clamp Leakage Current Meter | AC 0.00mA~1200A | 0.01mA | Φ68mm |
ETCR6800D | AC/DC Clamp Current Meter |
AC 0.0A~1500A DC 0.0A~2000A |
0.1A |
Package | Outer Package | Carton |
Inner Package | Cloth bag | |
Accessory | Meter | 1 PCS |
Communication Cable | 1 PCS | |
CD | 1 COPY | |
Cloth bag | 1 PCS | |
Manual | 1 PCS | |
Certificate | 1 PCS | |
Warranty Card | 1 PCS |