ETCR030 Clamp High Accuracy Leakage Current Sensor-ETCR

ETCR030 Clamp High Accuracy Leakage Current Sensor

Product Characteristics

1:High accuracy AC leakage currenthiger harmonic current phasepower energypowerpower factor measurement etc.

2:Range:0.00mA~30A AC

3:Turn Ratio:800:1

4:Resolution : 0.01mA

5:Accuracy Class : 1.0

6:Safety Class:   CATⅢ600V

7:CT Structure:Clamp

8:CT Size:25mm x 30mm

ETCR030 High Accuracy Clamp leakage current sensor for AC leakage current, current, high harmonic current, phase, power, power factor and other detection. Range: 0.000mA~60.0A, jaw size is 25mm x 30mm. The sensor adopts the clamp-shaped structure, which can be measured without disconnecting the measured circuit. The permalloy iron core and double-layer shielding technology are used to ensure the accuracy and stability of the measurement. Non-contact measurement methods are adopted, and the operation is safe and simple. It can be connected to phase detection analyzers, industrial control devices, data loggers, oscilloscopes, harmonic analyzers, power quality analyzers, and high-precision digital multimeters.

 ETCR030 High Accuracy Clamp leakage current sensor

1. Coil tap      2. Coil tap      3. Shielding ground

4. Sensor output plug (3.5mm audio plug)     5. Output wire (2.5mm)

6. Trigger (open and close the clamp)        7. Clamp

 Function  High accuracy AC leakage current、higer harmonic current、 phase、power energy、power、power factor measurement
 Model  ETCR030
 Range  0.00mA~30A 
 Resolution  0.01mA
 Accuracy Class  1.0
  Phase Error  ≤2°
 Turn Ratio  800:1
 Reference Load  0 ~300mA ≤ 300Ω
 0 ~ 3A ≤ 30Ω
 0 ~ 30A ≤ 3Ω
 Clamp Size   25mmx30mm
 Weight  180g
 Output Interface  Shielded wire 1.5m, wire terminal interface: φ3.5mm Audio plug/BNC plug/4.0mm Double banana plug(Can be customized)
 Frequency  45Hz~100KHz
 Insulating Strength  AC3700V/rms ( between the core and coil)
 Safety Class  CATⅢ600V
 Output Method  Current sensing output
 Working Temperature  -15℃~50℃


Model

Range

Resolution

Accuracy Class

Phase Error

Turn Ratio

Reference Load

Clamp Size

ETCR016

0.00mA20A AC 

0.01mA

1.0

≤2°

800:1

≤120Ω

φ16mm

ETCR030

0.00mA30A AC 

0.01mA

1.0

≤2°

800:1

≤100Ω

25mm×30mm

ETCR040

0.00mA40A AC 

0.01mA

1.0

≤2°

800:1

≤80Ω

35mm×40mm

ETCR068

0.00mA60A AC 

0.01mA

1.0

≤2°

800:1

≤50Ω

φ68mm

ETCR080

0.00mA60A AC 

0.01mA

1.0

≤2°

800:1

≤50Ω

80mm×80mm


ETCR016/ETCR030/ETCR040/ETCR068/ETCR080 Clamp High Accuracy Leakage Current Sensor